SKAT-70D-N
DIELECTRIC TEST APPARAT
The device is designed for testing and diagnosing the insulation of power cables, surge suppressors, solid dielectrics, protective equipment and other objects and materials that require high voltage for testing. Can also be used as a high voltage alternating and direct current generator.
It has a bright six-inch liquid crystal display with a detailed display of all main and additional test parameters (rms current and voltage, peak voltage, average output current, output power, leakage current for 10 seconds).
The SKAT-70D device has advanced functionality. In addition to the manual and automatic modes, a test mode using built-in programs is implemented — the device will dial the specified voltage at the speed specified in the program automatically, withstand the specified time, remove the voltage and display a full report on the screen. The parameters and names of 10 programs can be edited using the user menu. Reports of the last 50 tests are saved in non-volatile memory and are available for viewing and printing using a printer connected via RS232 (optional). There is a real time clock.
There is an automatic mode for preliminary burning of defective insulation. This mode is used in case of insulation breakdown in couplings and in floating breakdowns to reduce the breakdown voltage to the operating voltage level of the burning installations. This mode can also be used to charge capacitors in acoustic shock wave generators.
DC voltage test | Output voltage | Regulation range, kV | from 1 to 71 |
Measurement range, kV | from 3 to 70 | ||
Limits of permissible relative measurement error, % |
± (2,0+0,04·((70/U)-1)), U - measured value, kV |
||
Pulsation amplitude, % | 3 | ||
DC voltage polarity | negative (positive optional) | ||
Output current | Maximum level, mA | 20 | |
Measurement range, mA | from 0,1 to 20 | ||
Limits of permissible relative measurement error, % |
± (2,0+0,1·((20/I-1)), I - measured value, mA |
||
AC voltage test | Output voltage | Regulation range, kV | from 1 to 51 |
Measurement range, kV | from 2 to 50 | ||
Limits of permissible relative measurement error, % |
± (2,0+0,04·((50/U)-1)), U - measured value, kV |
||
Pulsation amplitude, % | 5 | ||
Output current | Maximum level, mA | 50 | |
Measurement range, mA | from 0,1 to 50 | ||
Limits of permissible relative measurement error, % |
± (2,0+0,1·((50/I-1)), I - measured value, mA |
||
Load capacity at maximum voltage | up to 2.5 nF | ||
System Settings | Test Modes |
■ Manual ■ Automatic ■ Bu program |
|
Voltage change rate, kV/s | 0,5; 1; 2; 5 | ||
Renge of user-defined timer values, min | from 1 to 60 | ||
Interfaces | Indication | LSD display | |
Device management |
Pushbutton and encoder |
||
Safety | Grounding |
■ Protective earth ■ Automatic earthing switch |
|
Protection |
■ Overvoltage and current protection ■ Shutdown in the event of a breakdown in the load ■ High voltage unit overheating protection ■ External signal lamp (option) |
||
High voltage disconnect systems |
■ Emergency stop button ■ Security lock (option) |
||
Power and Consumption Options | AC supply voltage, V | from 198 to 242 | |
Power supply frequency, Hz | from 49 to 51 | ||
Maximum power consumption | 2800 В•А | ||
Maximum current consumption, A |
15 |
Control unit | |||
Height, mm | 180 | ||
Width, mm | 450 | ||
Length, mm | 300 | ||
Weight, kg | 17,5 | ||
High-voltage unit | |||
Height, mm | 650 | ||
Width, mm | 370 | ||
Length, mm | 350 | ||
Weight, kg | 29 |
Packing dimensions, HхWхL, m |
0,6 х 0,37 х 0,24 | 0,52 х 0,44 х 0,70 |
Packed weight, kg | 22 | 47 |
Packing volume, m3 | 0,05 | 0,16 |