СКАТ-70D

DIELECTRIC TEST APPARAT

The device is designed for testing and diagnosing the insulation of power cables, surge suppressors, solid dielectrics, protective equipment and other objects and materials that require high voltage for testing. Can also be used as a high voltage alternating and direct current generator.

Price
RUB360,000
items
18months
Cost of verification
9 000



It has a bright six-inch liq­uid crys­tal dis­play with a detailed dis­play of all main and addi­tion­al test para­me­ters (rms cur­rent and volt­age, peak volt­age, aver­age out­put cur­rent, out­put pow­er, leak­age cur­rent for 10 seconds).
 
 

The SKAT-70D device has advanced func­tion­al­i­ty. In addi­tion to the man­u­al and auto­mat­ic modes, a test mode using built-in pro­grams is imple­ment­ed — the device will dial the spec­i­fied volt­age at the speed spec­i­fied in the pro­gram auto­mat­i­cal­ly, with­stand the spec­i­fied time, remove the volt­age and dis­play a full report on the screen. The para­me­ters and names of 10 pro­grams can be edit­ed using the user menu. Reports of the last 50 tests are saved in non-volatile mem­o­ry and are avail­able for view­ing and print­ing using a print­er con­nect­ed via RS232 (option­al). There is a real time clock.



There is an auto­mat­ic mode for pre­lim­i­nary burn­ing of defec­tive insu­la­tion. This mode is used in case of insu­la­tion break­down in cou­plings and in float­ing break­downs to reduce the break­down volt­age to the oper­at­ing volt­age lev­el of the burn­ing instal­la­tions. This mode can also be used to charge capac­i­tors in acoustic shock wave generators.
 
 

Изображения
 
DC voltage test Output voltage Regulation range, kV from 1 to 71
Measurement range, kV from 3 to 70
Limits of permissible relative measurement error, %

± (2,0+0,04·((70/U)-1)),  

U - measured value, kV

Pulsation amplitude, % 3
DC voltage polarity negative (positive optional)
Output current Maximum level, mA 20
Measurement range, mA from 0,1 to 20
Limits of permissible relative measurement error, %

± (2,0+0,1·((20/I-1)), 

I  - measured value, mA

AC voltage test Output voltage Regulation range, kV from 1 to 51
Measurement range, kV from 2 to 50
Limits of permissible relative measurement error, %

± (2,0+0,04·((50/U)-1)), 

U - measured value, kV

Pulsation amplitude, % 5
Output current Maximum level, mA 50
Measurement range, mA from 0,1 to 50
Limits of permissible relative measurement error, %

± (2,0+0,1·((50/I-1)), 

I - measured value, mA

Load capacity at maximum voltage up to 2.5 nF
System Settings Test Modes

■ Manual

■ Automatic

■ Bu program

Voltage change rate, kV/s 0,5; 1; 2; 5
Renge of user-defined timer values, min from 1 to 60
Interfaces Indication LSD display
Device management

Pushbutton and encoder

Safety Grounding

■ Protective earth

■ Automatic earthing switch

Protection

■ Overvoltage and current protection

■ Shutdown in the event of a breakdown in the load

■ High voltage unit overheating protection

■ External signal lamp (option)

High voltage disconnect systems

■ Emergency stop button

■ Security lock (option)

Power and Consumption Options AC supply voltage, V from 198 to 242
Power supply frequency, Hz from 49 to 51 
Maximum power consumption 2800 В•А
Maximum current consumption, A

15

Packing dimensions

 

Control unit
Height, mm 420
Width, mm 340
Length, mm 220
Weight, kg 14
High-voltage unit
Height, mm 650
Width, mm 370
Length, mm 360
Weight, kg 29

 

 

Logistics

 

Packing dimensions, 

HхWхL, m

0,67 х 0,67 х 0,4
Packed weight, kg 66
Packing volume, m3 0,18

 

Нет товаров